State Recommends Five-Year Hazardous Waste Permit Renewal for Tech Ord Facility Near Clear Lake, Mandates Groundwater Remediation Plan

Northeast Radio SD News – Clear Lake, SD - The South Dakota Department of Agriculture and Natural Resources has recommended renewing a five-year hazardous waste storage and thermal treatment permit for Tech Ord, a division of AMTEC Corporation, at its energetic materials manufacturing plant north of Clear Lake while requiring an engineering plan to remediate historical shallow groundwater contamination on the property.
Under a public notice signed by Hunter Roberts, secretary of the South Dakota Department of Agriculture and Natural Resources, the department’s Waste Management Program is recommending that the South Dakota Board of Minerals and Environment issue Permit No. SDD981549983-2026 for Tech Ord’s facility at 47600 180th Street, located about one mile north of Clear Lake across three adjacent parcels in Sections 11 and 12 of Township 115 North, Range 49 West in Deuel County.
Tech Ord manufactures energetic products used in military, space, and commercial markets. The 64-page final permit governs on-site storage, open burning, open detonation, indoor confined thermal treatment, environmental monitoring, and corrective action for reactive hazardous wastes generated during production. Tech Ord submitted its permit renewal application in November 2025, followed by updated soil and groundwater laboratory reports, a revised closure cost estimate, a March 2026 alternative technology assessment, an April 2026 integrated contingency plan, and a May 2026 site map revision.
45-Day Public Comment and Petition Window
Under state administrative rules, the department’s recommendation becomes the final decision of the Board of Minerals and Environment unless an adversely affected person files a formal petition for a contested case hearing within 45 days of the public notice publication date. Once issued, the renewed permit remains valid for five years through 2031.
Public review documents are posted through the department’s public notice portal at danr.sd.gov/public/default.aspx, and questions may be directed to Kristina Proietti with the Waste Management Program at 523 East Capitol Avenue in Pierre, by phone at 605-773-3153, or by email at kristina.proietti@state.sd.us. The notice advises anyone mailing a petition to use certified or registered mail, obtain a hand-stamped postmark, or include an affidavit of mailing because standard U.S. Postal Service mail may not be postmarked on the day it is dropped off.
On-Site Waste Restriction, Storage Bunkers, and Treatment Limits
The permit strictly prohibits Tech Ord from importing or accepting any hazardous waste from off-site or foreign sources, limiting operations exclusively to reactive hazardous wastes generated on-site. Combined normal thermal treatment across the facility is capped at up to 44,000 pounds of reactive waste per year, divided between outdoor open-burn units and an indoor filtered treatment building.
Across Modules III, IV, and V, the permit establishes specific storage capacities and batch limits for each authorized unit:
· Energetic Wastes Storage Unit (Bunkers 32 through 40): Nine earth-covered, waterproofed reinforced-concrete Type I outdoor explosive magazines with steel doors are authorized to store packaged reactive wastes—such as pyrotechnic and high-explosive powders or pellets, detonators, primers, leads, tracers, delays, impulse cartridges, piston actuators, and loaded rings—for longer than 90 days. Each bunker is restricted to the least of 4.85 cubic yards, 5,000 pounds total weight, or 100 pounds net explosive weight, and reactive waste containers must sit at least 50 feet from property lines and undergo weekly inspections and annual inventories.
· Open Burning Units 1, 2, and 3: Three steel burn fixtures—designated as the Burn Box, Strong Box, and Burn Troughs—sit on curbed concrete sacrificial pads underlain by high-density polyethylene secondary containment liners, leak detection systems, and retractable precipitation covers. These units may treat up to 20,300 pounds annually of reactive wastes containing up to 15 percent by weight of toxic metals (barium, cadmium, chromium, or lead), including up to 8,300 pounds of impulse cartridges in Unit 1, 3,000 pounds of lead and piston actuators in Unit 2, and 9,000 pounds of high-explosive powders, pyrotechnic powders, and tracers in Unit 3. Individual burns are capped at 25 pounds net explosive weight (and 50 to 100 pounds total weight depending on the unit), with an eight-hour daily average limit of 100 pounds total weight per hour.
· Open Detonation Unit 4 (Detonation Tank): A steel detonation fixture may temporarily replace a burn fixture on Units 1 through 3 only after a written request and prior state approval. When authorized, open detonation is capped at the lesser of eight pounds total weight or two pounds net explosive weight per batch and 24 pounds total weight (or six pounds net explosive weight) per hour.
· Confined Treatment Unit: Reactive wastes containing more than 15 percent by weight of barium, cadmium, chromium, or lead must be treated indoors inside an enclosed steel confinement building located 100 feet south of the open-burn pads. Equipped with two gas-fired chambers—a Burn Barrel and a Detonation Barrel—the unit routes exhaust through a three-stage air pollution control system featuring a cyclone, baghouse, and high-efficiency particulate air (HEPA) filters. Normal annual capacity is capped at 23,700 pounds, including up to 10,000 pounds of powder-contaminated plastic bags and explosive-contaminated cardboard, 10,000 pounds of contaminated personal protective equipment and production aids, 1,500 pounds of detonators, 1,000 pounds of primers, 1,000 pounds of loaded rings and metal parts, and 200 pounds of delays and cutter cartridges. Individual chamber batches cannot exceed 10 grams net explosive weight on a TNT-equivalency basis.
Treating wastes containing mercury, pesticides, dioxins, furans, or polychlorinated biphenyls (PCBs) is prohibited in both the outdoor and indoor units. Tech Ord must also maintain an ongoing evaluation of alternative non-open-burn technologies and submit monthly treatment summaries to the state within 15 days of the end of each month.
Weather Cutoffs, Emergency Reporting, and Liability Coverage
To limit off-site emissions and safety risks, open burning and open detonation are restricted to daylight hours between 7 a.m. and 5 p.m., for no more than eight hours per day and 2,088 cumulative hours per calendar year. Outdoor thermal treatment is prohibited during measurable precipitation or whenever sustained wind speeds reach 15 mph or higher. Both outdoor open-burn operations and indoor Confined Treatment Unit operations must be immediately suspended and evacuated whenever lightning is detected within eight miles of the plant.
Visible air emissions from any single treatment unit may not exceed 20 percent opacity outside of brief startup, shutdown, or malfunction periods, and boundary noise must remain within federal Occupational Safety and Health Administration and local limits. Based on a previously submitted Human Health Risk Assessment modeling maximum permitted waste volumes, state regulators noted no significant lifetime cancer risks, chronic hazard estimates, or acute inhalation hazards were identified.
Tech Ord must orally report any hazardous release, fire, or explosion that could threaten public drinking water, health, or the environment outside the facility to the state within 24 hours, followed by a written report within five days. Copies of the plant’s contingency plan must be maintained with local police, fire departments, hospitals, and emergency response teams, and Tech Ord must carry at least $4 million per occurrence and $8 million in annual aggregate third-party liability coverage combining sudden and nonsudden accidental occurrences alongside state-approved closure financial assurance.
Groundwater Contamination and 60-Day Corrective Action Requirement
While the permit requires semi-annual soil testing for 34 contaminants of concern and ongoing groundwater monitoring beneath the current treatment units, Modules VI and IX also address historical contamination at two designated Areas of Concern on the property.
At a former open-burning and open-detonation ground designated as AOC-001—located roughly 800 feet northwest of the current treatment facility—past operations left elevated lead, cadmium, and chromium in surface soils. In November 2016, Tech Ord excavated contaminated soil exceeding federal industrial screening levels, hauled it to a permitted off-site landfill, and backfilled the area with clean soil.
However, shallow groundwater sits between two and 12 feet below the surface at AOC-001, and semi-annual sampling confirmed elevated concentrations of explosive constituents—including perchlorate, HMX, and RDX—in two shallow monitoring wells, MW-2 and MW-3, indicating historical surface residues migrated into the shallow water table. Under the renewed permit, Tech Ord must submit a written engineering feasibility plan within 60 days of permit issuance proposing a detailed corrective action plan to remediate the groundwater contamination at AOC-001, and must report annually to the state on cleanup effectiveness.
A second site, the Building 106 product testing area designated as AOC-002, showed elevated toxicity metals in a limited area of surface soil during an October 2013 assessment. Because AOC-002 remains in active use for product testing, the permit requires a full site assessment and corrective action plan once that testing area eventually closes.